Overview

下载

The s::can spectrometer probes from HydroSpan Ltd operate using the same measuring principle: Spectrometry. The spectrometer probes are the first and only instruments in the world that can measure optical spectra from 190 to 720 nm directly in liquid media. The materials contained in the medium deteriorate a light beam emanated by a lamp that transfers through the liquid. After contact, its intensity is measured by a sensor over a variety of wavelengths specific to the application.

s::can’s proprietary algorithms analyze and decompose the spectral data to provide measurements for many important parameters including: nitrate, nitrite, COD, BOD, TSS, dissolved H2S and many more. No moving parts and no reagents are used, resulting in extremely low operating costs.


spectro::lyser™

Spectro::lyser™ UV monitors depending on the application an individual selection of: NO3-N, COD, BOD, TOC, DOC, UV254, NO2-N, BTX, fingerprints and spectral alarms, temperature and pressure.

  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry over the total range (220-720 nm or 220-390 nm)
  • multiparameter probe
  • ideal for surface water, ground water, drinking water and waste water
  • long term stable and maintenance free in operation
  • factory precalibrated
  • automatic cleaning with compressed air
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • robust and precise adaption of optical path lengths to 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
  • easy mounting without clogging

 spec
carbo::lyser™ II / III

carbo::lyser™ II monitors TSS & UV254 or TSS & COD or TSS & BOD or Turbidity & TOC or Turbidity & DOC.

  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry
  • multiparameter probe
  • long term stable and maintenance free in operation
  • factory precalibrated
  • automatic cleaning with compressed air
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • automatic compensation of cross sensitivities
  • ideal for surface water, ground water, drinking water and waste water
  • robust and precise adaption of optical path lengths to 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
  • easy mounting without clogging

cabo.png
multi::lyser™ II / III

multi::lyser™ II monitors NO3-N & one organic parameter (COD, BOD, TOC, DOC or UV254)

multi::lyser™ III montiors turbidity / TSS & NO3-N & one organic parameter (COD, BOD, TOC, DOC or UV254)

  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry
  • multiparameter probe
  • ideal for surface water, ground water, drinking water and waste water
  • long term stable and maintenance free in operation
  • factory precalibrated
  • automatic cleaning with compressed air
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • robust and precise adaption of optical path lengths to
  • 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible easy mounting without clogging

multi
nitro::lyser™ II
 nitro::lyser™ II monitors TSS & NO3-N or turbidity & NO3-N
  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry
  • multiparameter probe
  • ideal for surface water, ground water, drinking water and waste water
  • long term stable and maintenance free in operation
  • factory precalibrated
  • automatic cleaning with compressed air
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • robust and precise adaption of optical path lengths to
  • 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
  • easy mounting without clogging

 multi
ozo::lyser II

ozo::lyser II monitors turbidity & ozone

  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry
  • multiparameter probe
  • ideal for drinking water
  • long term stable and maintenance free in operation
  • factory precalibrated
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • robust and precise adaption of optical path lengths to 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
  • easy mounting without clogging

cabo.png
sulfi::lyser

sulfi::lyser II monitors TSS & HS & H2S*

sulfi::lyser III monitors TSS & HS & H2S* & NO3-N

sulfi::lyser IV monitors TSS & HS & H2S* & NO3-N

  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry
  • multiparameter probe
  • long term stable and maintenance free in operation
  • factory pre-calibrated
  • automatic cleaning with compressed air
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • automatic compensation of cross sensitivities
  • ideal for surface water, ground water, drinking water and waste water
  • robust and precise adaption of optical path lengths to 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
  • easy mounting without clogging

color
uv::lyser II
 uv::lyser II monitors turbidity & UV254 or TSS & UV254
  • s::can plug & measure
  • measuring principle: UV-Vis spectrometry
  • multiparameter probe
  • ideal for surface water, ground water, drinking water and waste water
  • long term stable and maintenance free in operation
  • factory pre-calibrated
  • automatic cleaning with compressed air
  • mounting and measurement directly in the media (InSitu) or in a flow cell (monitoring station)
  • operation via s::can terminals & s::can software
  • robust and precise adaption of optical path lengths to 35 mm, 15 mm, 5 mm, 2 mm, 1 mm or 0.5 mm possible
  • easy mounting without clogging
color
  • Measurement Parameters
  • Data Sheet
  • Applications
  • Download